ZXCT1008/1009/1010/1011/1012 - Current output current monitors

ZXCT1008/1009/1010/1011/1012 - Current output current monitors

ZXCT current monitors with a current output convert a high-side current measurement to a ground referred current output. This greatly simplifies high-sided current measurements. The devices enable gain to be set by a single external transistor. The common-mode voltage of the monitored current can be substantially increased by the addition of 1 or 2 transistors (see AN45 for more information)

    Features
  • Accurate high-side current sensing
  • Output voltage scaling
  • Up to 2.5V sense voltage
  • 2.2 - 20V supply range
  • 1% typical accuracy
    Applications
  • Battery chargers
  • Smart battery packs
  • DC motor control
  • Over current monitor
  • Power management
Part number   Description VIN


(V)
Accuracy
@ VSENSE
Typical
quiescent
current
(µA)
Gain
output/VSENSE
Bandwidth


(MHz)
Price
($) 1k
Package
 ZXCT1008 datasheet for this product (pdf) Wide ambient
temperature range
2.5 to 20(1) ± 2.5%
@ 100mV
4 10mA/V 2 0.400 SOT23
 ZXCT1009 datasheet for this product (pdf) Current output 2.5 to 20(1) ± 2.5%
@ 100mV
4 10mA/V 2 0.371 SM8
SOT23
 ZXCT1010 datasheet for this product (pdf) Current output with improved offset 2.5 to 20 ± 2.5%
@ 100mV
3.5 10mA/V 2 0.491 SOT23-5
 ZXCT1011 datasheet for this product (pdf) Improved temperature drift 2.5 to 20(1) ± 2.5%
@ 100mV
4 10mA/V(2) 1.5 0.491 SOT23-5
 ZXCT1012 datasheet for this product (pdf) Reduced height micro-power current monitor 2.5 to 20 ± 2.5% @ 100mV 3.5 10mA/V 2 0.543 TDFN3x3-5
TSOT23-5
 ZXCT1020 datasheet for this product (pdf) Precision high-side current monitor 2.7 to 20 ±2%
@ 100mV
25 Prog 3 0.543 SOT23-5
 ZXCT1050 datasheet for this product (pdf) Wide input range current monitor 2.7 to VCC 2V ±3% @ 100mV 45 Prog 0.5 0.543 SOT23-5


(1) Relative to IOUT
(2) Gain with RSHUNT at 120Ω

 Indicative/budgetary information dependent on package and tolerance where applicable

Experiencing problems with this export tool? Some of our users have reported difficulties trying to save the Excel file after they have opened it. To avoid these problems whilst saving, we recommend selecting the "Save" option at the prompt to save the file to your local PC then opening it, rather than opening the file directly in your browser.

 Design tools
*

Click on the individual part number for product information and product model (where available).
For more spice model information click here.

Back to top

More info

*